Solar quotes mix electrical units, battery chemistry and municipal paperwork. These are the terms you'll meet most often, in the order you'd come across them: power and energy first, then panels, inverters, batteries and the rules for connecting to the grid.

Solar glossary

kW (kilowatt)
Power at a moment: how hard something pulls. 1 kW = 1 000 W. A kettle draws about 2.2 kW.
kWh (kilowatt-hour)
Energy over time, and what you pay for: one "unit" on your bill. 1 kW for 1 hour, or 100 W for 10 hours.
kVA (kilovolt-ampere)
Apparent power, used to rate inverters and generators. For resistive loads kVA equals kW; with motors, real power is lower (kW = kVA × power factor, often 0.8). Check an inverter's continuous output in watts.
kWp (kilowatt-peak)
The rated output of solar panels under standard test conditions (1 000 W/m², 25 °C). Ten 550 W panels make a 5.5 kWp array.
Peak sun hours
The day's sunshine expressed as hours of full-strength sun; equal to the kWh a day 1 kWp of panels makes before losses. About 4.4 to 6.1 in South Africa. See peak sun hours by city.
Performance ratio
The share of the theoretical output a real system delivers after heat, dust, shade, wiring and inverter losses: usually 75–85%.
Grid-tied inverter
Feeds solar power into the house and the grid; switches off when the grid fails (for safety), so gives no backup. See grid-tied systems.
Hybrid inverter
Combines a solar charger, battery charger and inverter: runs the house from solar, battery and grid and keeps a backup circuit on during outages. See hybrid inverters.
Off-grid system
Solar, battery and inverter with no grid connection at all, often with a generator as backup. Common on farms and lodges. See off-grid systems.
MPPT
Maximum power point tracking: electronics in a charge controller or inverter that keep the panels at the voltage where they give the most power. Up to 30% more harvest than PWM.
PWM controller
A simpler, cheaper charge controller that connects panels almost directly to the battery. Fine for small 12 V systems.
String
Panels wired in series: their voltages add up, the current stays the same. A string of ten panels at 41 V works at about 410 V.
Voc and Isc
Open-circuit voltage and short-circuit current of a panel. Voc rises on cold mornings, so strings are sized so that cold Voc stays under the inverter's maximum input voltage.
Depth of discharge (DoD)
How much of a battery's capacity is used before recharging. Lithium is usually run to 80–90%, lead-acid to about 50%.
Cycle life
How many charge–discharge cycles a battery lasts before it falls to about 70–80% of its capacity. LiFePO4: 3 000–6 000; lead-acid: 300–1 500.
LiFePO4
Lithium iron phosphate, the battery chemistry most used for home solar: safe, long-lived and stable in heat.
BMS
Battery management system: electronics inside a lithium battery that balance the cells and protect them from over-charge, deep discharge, high current and heat. It talks to the inverter over a communication cable.
Ah (amp-hour)
Battery capacity at a given voltage. kWh = Ah × V ÷ 1 000. See the battery calculator.
Surge (peak) rating
The power an inverter can deliver for a few seconds to start motors in fridges, pumps and compressors, often about twice its continuous rating.
Pure sine wave
A smooth AC waveform like the grid's. Needed by motors and electronics; all good solar inverters produce it.
Essential loads (backup circuit)
The circuits wired to stay on through the inverter during an outage: usually lights, plugs, fridge, Wi-Fi, gate and alarm, but not the geyser and stove.
Monocrystalline, half-cut and bifacial
Monocrystalline panels (black) are the standard today. Half-cut cells reduce losses and shading effects; bifacial panels also collect light reflected onto their back, useful on ground mounts and carports.
Tier 1
A financial ranking of panel manufacturers by bankability, not a quality certificate. Look for IEC 61215 and IEC 61730 certification and a local warranty contact.
Degradation
The slow loss of panel output with age: typically about 0.4–0.55% a year, with 80–87% guaranteed after 25 or 30 years.
SSEG
Small-scale embedded generation: the term municipalities and Eskom use for rooftop solar and other generators connected to their network. They must be registered. See compliance.
NRS 097-2-1
The South African standard for grid-connected inverters; municipalities only approve inverters on their list of compliant models.
Certificate of Compliance (CoC)
Issued by a registered electrician for the electrical installation, including the solar system. Needed for insurance, registration and when selling the house.
Net metering and feed-in
Credit for solar power exported to the grid. Some municipalities pay or credit exports from registered systems, at a rate below the purchase tariff; many don't. See the savings calculator.
Isolators, DC breakers and SPDs
Switches and fuses that let the panels and battery be disconnected safely, and surge protection devices that guard against lightning-induced surges, important on the Highveld.
Wheeling
Moving power from a generator on one site to a buyer on another over the municipal or Eskom network, paying a fee. Used by larger businesses buying solar power from a solar farm.

Frequently asked questions

What is the difference between kW and kWh?
kW is power at a moment; kWh is energy over time. An inverter's size is in kW (or kVA); a battery's capacity and your bill are in kWh.
Is a 5 kVA inverter the same as a 5 kW inverter?
Not always. Many modern hybrid inverters give their full rating in watts, but some kVA-rated units give only about 80% of it in kW. Compare the continuous output in watts.
What does kWp mean on a solar quote?
The total rated output of the panels: the number of panels × their wattage. 12 × 550 W = 6.6 kWp.

Get free solar quotes

Tell us what you need and where. An installer or supplier who works in your area quotes you directly. Free, no obligation.

Size it roughly (optional)

Tick what must keep running when the power is off. The estimate goes into your request so installers can quote closer to what you need.

Hours of backup
Sun where you are

5.0 kWh per kWp a day

–kVA inverter
–kWh battery
–kWp panels

Tick a few loads or enter your monthly units to see a size.

A rough guide only. An installer confirms the size after looking at your bill, roof and distribution board.

Tick what applies (optional)

Free and no obligation. By sending you agree that we may share your request with a suitable installer or supplier. See our privacy policy.